Vertical multistage stainless steel centrifugal pump for high-rise building water supply, industrial circulation and domestic water applications. Energy-efficient design with compact vertical footprint, stainless steel main components for hygienic and corrosion-free operation.

Key Specifications

Flow Rate 2-200 m3/h
Head 5-280 m
Power 0.75-110 kW

Inquiry Now →

Product Overview

The CDLF Series is a vertical multistage stainless steel centrifugal pump for clean water transfer, pressure boosting and circulation in residential, commercial and light industrial applications. Stainless steel wetted components ensure hygienic, corrosion-resistant performance in a compact vertical footprint.

Widely used in high-rise water supply, industrial circulation, domestic distribution and water treatment. Also known as Vertical Multistage Centrifugal Pump or Stainless Steel Booster Pump.

Key Features

  • High operating efficiency with optimised hydraulic design for reduced energy consumption
  • Compact vertical arrangement minimises floor space requirements in pump room installations
  • Stainless steel wetted components ensure hygienic, corrosion-resistant water transfer
  • Stable operating performance with rational structural design for extended service life
  • Elegant, modern exterior suitable for exposed installations in building mechanical rooms
  • Multistage impeller configuration delivers high head within a single integrated unit

Applications

  • High-rise building water supply and domestic pressure boosting systems
  • Industrial water circulation and process water transfer
  • Domestic potable water distribution networks
  • Environmental water treatment process circulation and pressurisation
  • Central air conditioning chilled water and hot water circulation circuits
  • Municipal and industrial water booster stations

Customer Benefits

Energy-Efficient Operation

The hydraulically optimised impeller design and efficient motor selection reduce power consumption during continuous operation, lowering utility costs over the pump service life.

Space-Saving Vertical Design

The vertical arrangement requires significantly less floor space than equivalent horizontal multistage alternatives, making the CDLF Series ideal for confined pump room layouts.

Hygienic Water Transfer

Stainless steel wetted components ensure clean, contamination-free water transfer suitable for domestic water supply and water treatment applications requiring hygienic conditions.

Extended Service Life

The rational structural design and corrosion-resistant stainless steel materials reduce component wear and extend maintenance intervals, lowering total cost of ownership.

Consistent Performance

The multistage impeller arrangement provides stable head and flow output across a wide operating range, accommodating system demand variations without performance degradation.

Wide Operating Range

With flow rates from 2 to 200 m³/h and heads from 5 to 280 m, the CDLF Series covers a broad spectrum of pressure boosting and circulation requirements.

Technical Specifications

Parameter Specification
Product Series CDLF Series
Pump Type Light-duty vertical multistage stainless steel centrifugal pump
Flow Rate 2-200 m³/h
Head 5-280 m
Motor Power 0.75-110 kW
Rotational Speed 2900 r/min
Outlet Diameter DN25-DN150
Main Material Stainless steel (wetted parts)
Installation Type Vertical

Model Designation

  • CDL:Lightweight vertical multi-stagecentrifugal pump
  • F:(Omitted for ordinary types)
    Overcurrent componentsMade
    of stainless steel 304 or 316L
  • 200:Rated flow rate m2/h
  • 40: Series × 10
  • 2A:2 small impeller A
  • B:1 smallimpeller B

Performance Data

Model Matched Motor(KW) Flow Rate(m²h) 1 1.2 1.6 2 24 2.8 3.2 Dimensions(mm) Pump Weight(kg)
B1 B2 H D1 D2
CDL(F2-20 0.75 Head(m) 18 17 16 15 13 12 10 304 250 554 170 142 20
CDLF2-30 0.75 27 26 24 22 20 18 15 322 250 572 170 142 20
CDLF)2-40 0.75 36 35 33 30 26 24 20 340 250 590 170 142 22
CDLF2-50 0.75 45 43 40 37 33 30 25 358 250 608 170 142 23
CDL(F2-60 0.75 54 52 50 45 40 36 30 376 250 626 170 142 26
CDLF2-70 0.75 63 61 57 52 47 41 35 394 250 644 170 142 26
CDL(F2-80 1.1 72 70 65 60 54 48 40 412 250 662 170 142 28
CDLF2-90 1.1 81 78 73 67 61 54 45 430 250 680 170 142 28
CDL(F2-100 1.1 90 87 81 75 67 59 50 448 250 698 170 142 29
CDL(F2-110 1.1 98 95 89 82 73 64 55 466 250 716 170 142 29
CDL(F2-120 1.5 108 104 98 90 81 71 60 494 295 789 190 155 35
CDLF2-130 1.5 116 114 106 98 89 78 65 512 295 807 190 155 35
CDL(F2-140 1.5 126 122 115 105 95 84 70 530 295 825 190 155 36
CDLF2-150 1.5 134 130 123 112 100 90 75 548 295 843 190 155 36
CDL(F2-160 2.2 144 139 132 120 107 96 80 566 295 861 190 155 37
CDLF2-170 2.2 153 148 140 128 114 102 85 584 295 879 190 155 37
CDLF2-180 2.2 161 157 148 136 121 108 90 602 295 897 190 155 41
CDLIF2-190 2.2 170 166 156 144 128 114 95 620 295 915 190 155 41
CDL(F2-200 2.2 179 175 164 151 135 120 100 633 295 928 190 155 42
CDLIF2-210 2.2 188 184 172 158 142 126 105 641 295 936 190 155 42
CDLF2-220 2.2 197 192 180 165 14配 132 110 659 295 954 190 155 43
CDLF2-230 3 206 201 189 174 156 139 115 687 330 1017 197 165 51
CDL(F2-240 3 215 210 197 182 163 146 120 705 330 1035 197 165 51
CDLF2-250 3 224 219 206 190 171 152 125 723 330 1053 197 165 52
CDLF2-260 3 232 228 214 198 179 158 130 741 330 1071 197

Selected model data shown. Contact us for full parameters and model selection.

Selection Guidance

To select the appropriate CDLF Series pump model, please provide the following information:

  • Required flow rate (m³/h)
  • Required head (m)
  • Pipeline diameter and connection type
  • Water source and liquid characteristics
  • Installation space constraints
  • Available voltage and frequency
  • Operating temperature range
  • Preferred motor power

Final model selection should be confirmed according to the actual duty point, system requirements and project conditions.

Installation and Maintenance

Installation Guidance

The pump should be installed on a level, stable foundation with adequate clearance for inspection and maintenance access. The inlet and outlet pipelines must be properly supported so that no external load is transferred to the pump connections.

Pre-Start Inspection

Before starting the pump, confirm the following:

  • Pump is securely mounted and level
  • Pipeline connections are complete and properly aligned
  • Inlet and outlet passages are unobstructed
  • Motor wiring is correct and terminals are secure
  • Rotational direction matches the arrow indicated on the pump casing
  • All fasteners are properly tightened

Routine Maintenance

Regular inspection should include:

  • Checking mechanical seals for leakage
  • Monitoring motor bearing temperature and vibration levels
  • Verifying that the pump maintains the required flow and head
  • Cleaning strainers and filters when necessary
  • Inspecting all pipeline connections for signs of wear or leakage

Available Configurations

  • Flow rates from 2 to 200 m³/h
  • Heads from 5 to 280 m
  • Motor powers from 0.75 to 110 kW
  • Rotational speed: 2900 r/min
  • Outlet diameters from DN25 to DN150
  • Different stage configurations for varying pressure requirements

FAQs

What is a CDLF Series Vertical Multistage Pump?

The CDLF Series is a light-duty vertical multistage centrifugal pump constructed primarily from stainless steel, designed for clean water transfer, pressure boosting and circulation in building, industrial and water treatment applications.

What is the flow range of the CDLF Series?

The CDLF Series offers flow rates from 2 to 200 m³/h.

What is the head range?

Available heads range from 5 to 280 m, achieved through multistage impeller configurations.

What liquids can this pump handle?

It is suitable for clean water and non-aggressive, non-explosive liquids without solid particles or fibres. The stainless steel wetted components make it suitable for hygienic water transfer applications.

Why is stainless steel used?

Stainless steel construction provides corrosion resistance, hygienic water transfer and a long service life, making the CDLF Series suitable for domestic water supply and water treatment applications.

Where can the CDLF Series be used?

It is widely used in high-rise building water supply, industrial circulation systems, domestic water distribution, water treatment plant circulation and central air conditioning water circuits.

Contact Chaodun

For product selection, technical data, performance information or project quotations, please contact Shanghai Chaodun Machinery Manufacturing Group Co., Ltd.

Website: https://chaodunpump.com

Email: [email protected]

WhatsApp: +86 186 5872 1239

Scroll to Top